Identify NEO 1500 and NEO 2100 plumbing, flow, temperature, freeze, and Sensor 1–3 fault screens without crossing the manual’s no-user-service boundary.
Choose the exact message shown on the topside panel.
| Display | Manual meaning | Manual response |
|---|---|---|
| Plumbing Error | Sensor 1 and Sensor 3 plugs are reversed | Qualified service swaps the two controller plugs. |
| Insufficient Flow | No water flow through the heater, or no water in it | Verify adequate flow through the heater. |
| Low Flow | Water flow through the heater is inadequate | Verify adequate heater flow. |
| Water Overheat | Water reached 110°F / 43°C | Wait for the water to cool. |
| Heater Overheat | Heater reached 118°F / 48°C | Wait for cooling and verify adequate heater flow. |
| Potential Freeze | A sensor detected low temperature | Jets and blowers run automatically until all three sensors recover. |
| Sensor 1 / 2 / 3 Open | The named sensor circuit is open | Check that sensor connection. |
| Sensor 1 / 2 / 3 Short | The named sensor circuit is shorted | Check the connection or replace that sensor. |
The NEO manuals state that the control contains hazardous voltage and no user-serviceable parts. Disconnect power before service, keep the access door closed, and use a licensed electrician or qualified service organization. Service Mode is limited to authorized dealers and spa manufacturers.
The NEO 1500 and NEO 2100 manuals share these operator-facing error screens, but their wiring and connected-load arrangements are not interchangeable. Confirm the control-pack model and its exact wiring diagram before service.