Heater Warranty Denied Over Water Chemistry: What to Do, and Which Brands Back Their Warranties

Parker ConleyParker Conley+ClaudeNovember 26, 2026
Pool tech checking the inside of a gas pool heater at an equipment pad

A heat exchanger leaks at 14 months. The claim goes in. The answer comes back: water chemistry, not covered. Now the customer wants to know if it was your fault.

Here is the short answer. Every big heater maker writes water chemistry limits into its manual or warranty. Damage from water outside those limits is not a defect, so it is not covered. The maker decides by looking at the metal and at the readings. You win a fair claim with three things: a log that shows the water was in range, photos that show the install matches the manual, and a calm appeal through the right people.

This post goes deeper than our pool equipment warranty guide, which covers terms, labor and filing. Here we stay on heaters, chemistry denials and what to do next.

Key Takeaways

  • The limits are in writing. Pentair says not following its chart will void the heater warranty.[1]PentairMasterTemp 125 Pool and Spa Heater Installation and User's Guide, Rev. C, March 2019. Chemical Balance section and Water Chemistry Parameters table.pentair.com Jandy lists exact pH, alkalinity, CYA, TDS and hardness limits in its warranty.[3]JandyUSA and Canada limited warranty, document H0333803 Rev Y. This is the file on jandy.com as of November 26, 2026.jandy.com
  • One pH fits all four. A pH of 7.6 sits inside the target range of every heater chart in this post.[1]PentairMasterTemp 125 Pool and Spa Heater Installation and User's Guide, Rev. C, March 2019. Chemical Balance section and Water Chemistry Parameters table.pentair.com[2]HaywardUniversal H-Series Owner's Manual, Section II, Maintaining Proper Water Chemistry. Read November 26, 2026.hayward.com[3]JandyUSA and Canada limited warranty, document H0333803 Rev Y. This is the file on jandy.com as of November 26, 2026.jandy.com[5]RaypakGas-Fired Pool and Spa Heater manual, models 206A to 406A, P/N 241236 Rev. 51, effective October 27, 2026. Water Chemistry section and ProTek Shield Assembly section.raypak.com
  • The install counts too. Tabs in the skimmer, a chlorinator ahead of the heater or no check valve can all sink a claim.[2]HaywardUniversal H-Series Owner's Manual, Section II, Maintaining Proper Water Chemistry. Read November 26, 2026.hayward.com[3]JandyUSA and Canada limited warranty, document H0333803 Rev Y. This is the file on jandy.com as of November 26, 2026.jandy.com
  • The maker looks at the metal. Pentair asks service centers for pictures of chemical damage, such as fin tubes and chemical readings.[8]PentairWarranty Claim Submission Instructions for service centers, Pentair Partners business documents.pentair.com
  • The homeowner holds the warranty. Federal law gives the consumer the right to sue. You are the expert witness with the records.[13]United States Code15 U.S.C. 2310, Remedies in consumer disputes, subsections (a)(3) and (d).law.cornell.edu
  • Warranty work pays little. Pros say the flat rate rarely covers the time. The payoff is new customers.

What the heater manuals actually say

Most pros have heard "bad chemistry voids the warranty." Fewer have read the numbers. We opened the current manuals and warranties for four brands. Here is what each one asks for.

Sources: Pentair[1]PentairMasterTemp 125 Pool and Spa Heater Installation and User's Guide, Rev. C, March 2019. Chemical Balance section and Water Chemistry Parameters table.pentair.com, Hayward[2]HaywardUniversal H-Series Owner's Manual, Section II, Maintaining Proper Water Chemistry. Read November 26, 2026.hayward.com, Jandy[3]JandyUSA and Canada limited warranty, document H0333803 Rev Y. This is the file on jandy.com as of November 26, 2026.jandy.com and Raypak.[5]RaypakGas-Fired Pool and Spa Heater manual, models 206A to 406A, P/N 241236 Rev. 51, effective October 27, 2026. Water Chemistry section and ProTek Shield Assembly section.raypak.com All values are in ppm except pH.

Three things stand out.

The brands do not agree on pH. Hayward wants 7.4 to 7.6.[2]HaywardUniversal H-Series Owner's Manual, Section II, Maintaining Proper Water Chemistry. Read November 26, 2026.hayward.com Raypak wants 7.6 to 7.8 for plaster and most other pools.[5]RaypakGas-Fired Pool and Spa Heater manual, models 206A to 406A, P/N 241236 Rev. 51, effective October 27, 2026. Water Chemistry section and ProTek Shield Assembly section.raypak.com The only number inside every range is 7.6. If you run mixed brands on your route, 7.6 is the safe target for the heater.

One manual disagrees with itself. The Pentair table lists 80 to 100 ppm as ideal alkalinity. A paragraph a page earlier says 100 to 140 ppm.[1]PentairMasterTemp 125 Pool and Spa Heater Installation and User's Guide, Rev. C, March 2019. Chemical Balance section and Water Chemistry Parameters table.pentair.com When a manual says two things, aim where they overlap, around 100 ppm, and write down why.

The language is strong. Pentair says heat exchanger damage from chemical imbalance is not covered, and not following its chart will void the warranty.[1]PentairMasterTemp 125 Pool and Spa Heater Installation and User's Guide, Rev. C, March 2019. Chemical Balance section and Water Chemistry Parameters table.pentair.com Hayward says damage from bad chemistry or excess hardness is not covered.[2]HaywardUniversal H-Series Owner's Manual, Section II, Maintaining Proper Water Chemistry. Read November 26, 2026.hayward.com Raypak says damage from poor water chemistry is not a warrantable defect.[5]RaypakGas-Fired Pool and Spa Heater manual, models 206A to 406A, P/N 241236 Rev. 51, effective October 27, 2026. Water Chemistry section and ProTek Shield Assembly section.raypak.com Pentair's warranty page says the same thing in plain terms: damage from not keeping chemistry within industry standards is excluded.[7]PentairPool Product Warranty Information page, read November 26, 2026.pentair.com

Low pH and low alkalinity eat copper. High pH with high hardness lays scale in the tubes. Jandy's JXi manual explains both. It says scale can form when pH climbs above 7.8, and acidic water below 7.2 tends to dissolve the copper tubing.[4]JandyPro Series JXi Gas-Fired Pool and Spa Heater Installation and Operation Manual, H0404700 Rev G, Section 5 and Section 9.1. Copy hosted by POOLCORP.poolcorp.com Our LSI calculator puts both sides into one number. Jandy calls an index between -0.3 and +0.3 ideal.[4]JandyPro Series JXi Gas-Fired Pool and Spa Heater Installation and Operation Manual, H0404700 Rev G, Section 5 and Section 9.1. Copy hosted by POOLCORP.poolcorp.com

The exclusions that are not about numbers

Perfect readings will not save a heater that was set up wrong. The documents list several install and service habits that void coverage on their own.

  • Tabs in the skimmer. Pentair, Hayward, Jandy and Raypak all say not to put sanitizer tablets in the skimmer.[1]PentairMasterTemp 125 Pool and Spa Heater Installation and User's Guide, Rev. C, March 2019. Chemical Balance section and Water Chemistry Parameters table.pentair.com[2]HaywardUniversal H-Series Owner's Manual, Section II, Maintaining Proper Water Chemistry. Read November 26, 2026.hayward.com[4]JandyPro Series JXi Gas-Fired Pool and Spa Heater Installation and Operation Manual, H0404700 Rev G, Section 5 and Section 9.1. Copy hosted by POOLCORP.poolcorp.com[5]RaypakGas-Fired Pool and Spa Heater manual, models 206A to 406A, P/N 241236 Rev. 51, effective October 27, 2026. Water Chemistry section and ProTek Shield Assembly section.raypak.com Jandy's warranty excludes chemicals added through the skimmer or upstream of the heater.[3]JandyUSA and Canada limited warranty, document H0333803 Rev Y. This is the file on jandy.com as of November 26, 2026.jandy.com
  • Chlorinator order. Hayward says the chlorinator must go after the heater, with a check valve between them.[2]HaywardUniversal H-Series Owner's Manual, Section II, Maintaining Proper Water Chemistry. Read November 26, 2026.hayward.com Jandy says sanitizing equipment goes last on the line, with an in-line check valve between the heater and any chemical feeder.[4]JandyPro Series JXi Gas-Fired Pool and Spa Heater Installation and Operation Manual, H0404700 Rev G, Section 5 and Section 9.1. Copy hosted by POOLCORP.poolcorp.com
  • Bonding. Jandy excludes damage from not grounding or bonding as specified.[3]JandyUSA and Canada limited warranty, document H0333803 Rev Y. This is the file on jandy.com as of November 26, 2026.jandy.com Raypak excludes electrolysis from a salt chlorine generator installed the wrong way.[6]RaypakPool Heater Limited Warranty, P/N 100-10000378 Rev. 10, effective October 14, 2026.raypak.com
  • Flow. Jandy excludes running a product below its minimum or above its maximum flow rate.[3]JandyUSA and Canada limited warranty, document H0333803 Rev Y. This is the file on jandy.com as of November 26, 2026.jandy.com Hayward lists improper flow next to bad chemistry as heat exchanger damage it does not cover.[2]HaywardUniversal H-Series Owner's Manual, Section II, Maintaining Proper Water Chemistry. Read November 26, 2026.hayward.com
  • A spent anode. Raypak's ProTek Shield is a sacrificial part that guards the heat exchanger from galvanic corrosion when it is bonded.[5]RaypakGas-Fired Pool and Spa Heater manual, models 206A to 406A, P/N 241236 Rev. 51, effective October 27, 2026. Water Chemistry section and ProTek Shield Assembly section.raypak.com The warranty does not cover damage from a worn-out shield that was not replaced.[6]RaypakPool Heater Limited Warranty, P/N 100-10000378 Rev. 10, effective October 14, 2026.raypak.com
  • Chemicals stored nearby. Raypak excludes damage from corrosive chemicals near the heater.[6]RaypakPool Heater Limited Warranty, P/N 100-10000378 Rev. 10, effective October 14, 2026.raypak.com Acid jugs next to the heater count.

The skimmer rule causes the most fights, because the customer often adds the tabs. A pro on Reddit explained why it hurts even when the pump runs most of the day:

“The problem is when the equipment shuts off, then the water in the skimmer and suction line becomes corrosively acidic as the tab degrades because it’s not flowing.”

Hayward also gives a step many techs skip. When you are fixing badly out-of-balance water, open the heater bypass so the bad water does not flow through the heat exchanger. Close it again once the water is balanced.[2]HaywardUniversal H-Series Owner's Manual, Section II, Maintaining Proper Water Chemistry. Read November 26, 2026.hayward.com That one habit protects the heater during a green-to-clean or a big acid dose.

How the maker decides

A chemistry denial is not a guess from the phone. The maker or its warranty tech looks at evidence.

Pentair's own instructions for service centers ask for pictures of chemical damage, naming fin tubes and chemical readings.[8]PentairWarranty Claim Submission Instructions for service centers, Pentair Partners business documents.pentair.com So the tech pulls the header and photographs the tube ends. Pitted, thin or green tubes point to acidic water. White crust points to scale.

Other parts tell the story too. Jandy calls the thermal regulator valve an indicator of how well the water balance has been kept. It says to replace the valve and balance the water if it shows scale or corrosion.[4]JandyPro Series JXi Gas-Fired Pool and Spa Heater Installation and Operation Manual, H0404700 Rev G, Section 5 and Section 9.1. Copy hosted by POOLCORP.poolcorp.com A sacrificial anode works the same way. If it is gone, the water or the bonding was working against the metal.

Warranty techs say they also test the pool water on the day of the visit, and many check for copper. A high copper reading tells them the heat exchanger has been dissolving into the pool. It is very hard to argue with that.

That means your log has to agree with the metal. A log that says pH 7.5 every week next to tubes that are paper thin will not win. A log with real, changing numbers, plus a note when the customer added tabs or the pool went off-route, is far more believable.

How to document chemistry so a claim holds up

Most claims are won or lost long before the heater fails. Records made on the day are worth much more than a story told later. Here is what to capture and when.

Sources: Raypak[6]RaypakPool Heater Limited Warranty, P/N 100-10000378 Rev. 10, effective October 14, 2026.raypak.com, Jandy[3]JandyUSA and Canada limited warranty, document H0333803 Rev Y. This is the file on jandy.com as of November 26, 2026.jandy.com and Pentair.[8]PentairWarranty Claim Submission Instructions for service centers, Pentair Partners business documents.pentair.com

A few habits make the log stronger.

  • Write real numbers. "Balanced" or "good" means nothing to a warranty desk. Write 7.6, not "OK." Our guide on how to log pool chemical readings covers the details.
  • Log what you added. The doses explain the readings. A big acid dose followed by a low pH reading tells a clear story.
  • Text the customer when they cause trouble. If you find tabs in the skimmer, take a photo and send it with a short note. Now the record shows you warned them.
  • Keep it with the pool, not in the truck. When a claim comes up 18 months later, you need to pull the history in minutes. See our guide to tracking equipment warranties.

Weekly service has a gap. You see the water once a week. If the customer adds chemicals or tabs between visits, your log will not show it. That is why notes about the customer's own habits matter as much as the numbers. If you take over a pool with a newer heater, test for copper on the first visit and write it down. That protects you if the heater fails next month.

What to do after a denial

Do not argue on the first call. Work the problem in order.

  1. Get the reason in writing. Ask what the maker found. Was it tube damage, a reading, a missing check valve or the install? You cannot answer a reason you do not know.
  2. Check it against your records. Be honest here. If your log shows a low pH stretch, or the chlorinator sits ahead of the heater, the denial may be fair. If your log shows real numbers in range and your photos match the manual, you have a case.
  3. Send the evidence. Send the log, the install photos and the failure-day test in one package. Keep it short. Point to the manual's chart and show that the numbers sit inside it.
  4. Go through your rep. The local rep or territory manager can reopen a claim, ask for an inspection or approve a goodwill part. If you do not know your rep, the branch manager at your distributor will.
  5. Help the homeowner write to the maker. The warranty belongs to the owner. More on that below.

Who sells the equipment matters here. Pros who install a lot of one brand often say their rep will go to bat for them. One pro on Reddit put the choice this way:

“We always recommend installing equipment that has the best representatives. Some areas it’s Hayward, others it’s Jandy, or Pentair.”

Ask about a goodwill offer even when the denial stands. Some makers will discount a replacement or cover a part when the heater is new and the case is close. It does not hurt to ask, and the rep is the person who can say yes.

The homeowner's legal rights

The heater warranty is a promise to the owner, not to you. Raypak's warranty, for example, runs to the original purchaser and owner.[6]RaypakPool Heater Limited Warranty, P/N 100-10000378 Rev. 10, effective October 14, 2026.raypak.com So the steps below are for your customer. You supply the records.

  • Write it down. The FTC tells consumers to contact the seller first. If that fails, write to the maker, and send it by certified mail with a return receipt.[11]Federal Trade CommissionWarranties, Consumer Advice, July 2023.consumer.ftc.gov
  • Report it inside the warranty period. The FTC says that if a defect is reported during the warranty, the company must fix it even if the warranty runs out before the repair is done.[11]Federal Trade CommissionWarranties, Consumer Advice, July 2023.consumer.ftc.gov
  • Report an unfair denial. If the company still does not fix it, the FTC says to report it to the FTC and the state attorney general.[11]Federal Trade CommissionWarranties, Consumer Advice, July 2023.consumer.ftc.gov
  • Know the federal law. The Magnuson-Moss Warranty Act covers consumer products, meaning things normally used for personal, family or household purposes.[12]Federal Trade CommissionBusinessperson's Guide to Federal Warranty Law.ftc.gov A consumer can sue a warrantor that breaks its warranty in state court. A consumer who wins may recover costs and attorney fees. A federal court case needs at least $50,000 in dispute. If the warranty sets up an informal dispute program, the consumer may have to use it first.[13]United States Code15 U.S.C. 2310, Remedies in consumer disputes, subsections (a)(3) and (d).law.cornell.edu
  • Small claims court. Many states have a small claims court for smaller amounts, but the limits and rules vary by state. Check your state court's website before you suggest it.

The written warranties also say the owner may have other rights that vary by state.[3]JandyUSA and Canada limited warranty, document H0333803 Rev Y. This is the file on jandy.com as of November 26, 2026.jandy.com[6]RaypakPool Heater Limited Warranty, P/N 100-10000378 Rev. 10, effective October 14, 2026.raypak.com This section is general information, not legal advice. For a large loss, the homeowner should talk to a lawyer in their state.

Be realistic about court. One pro who asked about suing a big maker heard this back:

“As for taking them to court it would probably need to be a really substantial amount to be worth it, and even then you'd have to be really confident you followed all their Warranty steps to a T to want to bother.”

If the denial is fair, turn it into a clean replacement job. Fix the cause first. Move the chlorinator, add the check valve, bond the heater, and get the water in range. Then quote the heater. A new exchanger bought on its own is short on coverage. Hayward gives a replacement heat exchanger 1 year, parts only, with no labor.[9]Hayward2026 Expert Line residential warranty terms, including the purchased replacement parts warranty.hayward.com Our post on repairing vs. replacing a pool heater walks through the math.

Which brands back their warranties best?

There is no fair scorecard for this. No maker publishes its denial rate. What follows is field sentiment, not fact, and it changes by region.

Ask a room of pros and you will hear every brand named as both the best and the worst. The pattern under the noise is the local rep. A brand with a fast, helpful rep in your area will feel like the best warranty in the business. The same brand with no rep in the next county will feel like the worst. Pros who buy a lot from one brand often say claims go smoother for them than for a homeowner calling alone.

Some common threads in what pros say:

  • Parts speed matters more than terms. A long warranty means little if the part takes three weeks. Pros tend to praise the brand that ships parts fast in their area.
  • Labor coverage varies. This one you can check. Raypak's warranty covers parts and labor for 2 to 3 years on most of its home gas heaters.[6]RaypakPool Heater Limited Warranty, P/N 100-10000378 Rev. 10, effective October 14, 2026.raypak.com Hayward covers 1 year of field labor on its Expert Line heaters.[9]Hayward2026 Expert Line residential warranty terms, including the purchased replacement parts warranty.hayward.com Jandy's warranty does not cover labor.[3]JandyUSA and Canada limited warranty, document H0333803 Rev Y. This is the file on jandy.com as of November 26, 2026.jandy.com
  • Online sales get less help. Makers limit or refuse coverage on equipment bought from unauthorized online sellers. Our warranty guide lists each brand's rule.
  • Support feels thinner than it used to. Many longtime pros say reps are harder to reach than a few years ago.

That last point came up on our own show. A manufacturer rep who spent years on the commercial side said this about what he hears from the market:

“That's something that we've heard from the market overall that has been lacking in the past couple years is support from the manufacturers.”

“20 Years in Commercial Pool,” Pool People Podcast

The practical answer: before you standardize on a brand, call its rep. Ask how warranty calls work in your area, how fast parts ship and who does the labor. The answer tells you more than any forum argument. For smaller brands trying to win pros with service, see our look at new equipment brands.

How to become a warranty station, and whether it pays

A warranty station, or authorized service center, is a pool company the maker sends warranty calls to. The maker pays for the visit at its own rate.

How to sign up

Most makers do not post an open application. You usually start with the local rep. Raypak is the clearest. Its Pro Network page asks for:

  • A business license
  • An HVAC license to work on its heat pumps and pool heaters
  • A completed W-9
  • General liability and auto liability insurance, with Raypak named as additionally insured

Raypak says members set their hourly rates, but it can negotiate them based on local market rates. To join, it tells you to contact your local sales rep.[10]RaypakRaypak Pro Network page for warranty service providers, read November 26, 2026.raypak.com

Pentair runs claims through a service team account number. Claims must go in within 15 days of the work. A service center needs approval from a Pentair rep before it replaces a whole product such as a heater. Pay follows the center's rate agreement.[8]PentairWarranty Claim Submission Instructions for service centers, Pentair Partners business documents.pentair.com

For other brands, pros describe the same path. You need a contractor's license, liability insurance and a good history of selling that brand. Pros often mention $1 million in coverage. Some areas are full, and a rep may not add new stations at all.

Does the work pay?

Not by the hour. Pros who do it say most makers pay a flat amount per job, and many report figures around $75 to $110 a call. That flat rate does not change when a job runs long or needs a second trip for parts. Some pros report a maker paying their hourly rate in their area, so it varies.

Compare that with your normal prices. On poolrates.fyi, pros report an average service call fee of about $162 and an average hourly rate of about $139.[14]poolrates.fyiNational service call fee and hourly rate figures shared by pool pros, January 2026 to November 2026. Figures here are the average of the values.poolrates.fyi A heat exchanger swap at a flat warranty rate can pay well under that.

It is still worth asking for more on a hard job. One warranty center on Reddit said:

“You might talk to your local rep about additional payment. Ours will pay extra on rare occasion.”

So why do it? Pros give three reasons.

  • New customers. Every call puts you in the backyard of a pool owner who just had a good experience with you.
  • Your own installs. You can fix your own customers' equipment fast, instead of waiting on another company.
  • Trust. Being factory trained is a selling point, especially with commercial accounts.

That last reason came up when we talked with a commercial pool manager who keeps factory-trained techs on some equipment:

“So we're still using them to come down because they have been factory trained and they're covered by warranty if they screw something up.”

“Inside a 350,000-Gallon Commercial Pool,” Pool People Podcast

A good rule: treat warranty work as marketing, not as a profit center. Take it if you have slow weeks and want new pools. Skip it if your schedule is already full of work at your own rates.

Protect the next heater from day one

The best warranty claim is the one you never file. On every heater install or takeover:

  • Put the chlorinator or feeder last, with a check valve between it and the heater.[2]HaywardUniversal H-Series Owner's Manual, Section II, Maintaining Proper Water Chemistry. Read November 26, 2026.hayward.com[4]JandyPro Series JXi Gas-Fired Pool and Spa Heater Installation and Operation Manual, H0404700 Rev G, Section 5 and Section 9.1. Copy hosted by POOLCORP.poolcorp.com
  • Bond the heater and keep the anode in place if the heater has one.[5]RaypakGas-Fired Pool and Spa Heater manual, models 206A to 406A, P/N 241236 Rev. 51, effective October 27, 2026. Water Chemistry section and ProTek Shield Assembly section.raypak.com
  • Bypass the heater during startups, stain treatments and big chemical doses.[2]HaywardUniversal H-Series Owner's Manual, Section II, Maintaining Proper Water Chemistry. Read November 26, 2026.hayward.com
  • Keep tabs out of the skimmer, and tell the customer why in writing.
  • Run pH near 7.6 and keep the LSI close to zero.
  • Register the heater and save the invoice on the day you install it.

Use our warranty claim helper to check coverage dates before you call. If the customer pushes back on the bill, our guide on customer-supplied parts covers how to set expectations up front.

Sources

  1. [1]Pentair, MasterTemp 125 Pool and Spa Heater Installation and User's Guide, Rev. C, March 2019. Chemical Balance section and Water Chemistry Parameters table. pentair.com (PDF)
  2. [2]Hayward, Universal H-Series Owner's Manual, Section II, Maintaining Proper Water Chemistry. Read November 26, 2026. hayward.com (PDF)
  3. [3]Jandy, USA and Canada limited warranty, document H0333803 Rev Y. This is the file on jandy.com as of November 26, 2026. jandy.com (PDF)
  4. [4]Jandy, Pro Series JXi Gas-Fired Pool and Spa Heater Installation and Operation Manual, H0404700 Rev G, Section 5 and Section 9.1. Copy hosted by POOLCORP. poolcorp.com (PDF)
  5. [5]Raypak, Gas-Fired Pool and Spa Heater manual, models 206A to 406A, P/N 241236 Rev. 51, effective October 27, 2026. Water Chemistry section and ProTek Shield Assembly section. raypak.com (PDF)
  6. [6]Raypak, Pool Heater Limited Warranty, P/N 100-10000378 Rev. 10, effective October 14, 2026. raypak.com (PDF)
  7. [7]Pentair, Pool Product Warranty Information page, read November 26, 2026. pentair.com
  8. [8]Pentair, Warranty Claim Submission Instructions for service centers, Pentair Partners business documents. pentair.com (PDF)
  9. [9]Hayward, 2026 Expert Line residential warranty terms, including the purchased replacement parts warranty. hayward.com (PDF)
  10. [10]Raypak, Raypak Pro Network page for warranty service providers, read November 26, 2026. raypak.com
  11. [11]Federal Trade Commission, Warranties, Consumer Advice, July 2023. consumer.ftc.gov
  12. [12]Federal Trade Commission, Businessperson's Guide to Federal Warranty Law. ftc.gov
  13. [13]United States Code, 15 U.S.C. 2310, Remedies in consumer disputes, subsections (a)(3) and (d). law.cornell.edu
  14. [14]poolrates.fyi, National service call fee and hourly rate figures shared by pool pros, January 2026 to November 2026. Figures here are the average of the values. poolrates.fyi