A good replumb follows the water. It goes pump, filter, heater, then chlorinator, with each piece where the manual wants it. It uses sweeps and 45s instead of a pile of hard 90s. It puts a union on every piece you will ever pull. It uses the right cement, waits the full cure time, and gets tested with water, never air.
This guide is for the tech or owner who just walked up to a pad that looks like a bowl of spaghetti. It covers the layout, the glue, cracked unions, pressure tests and broken pipe. It also covers how to price the job and talk to the customer. We read the pump, heater, filter and salt cell manuals, the cement maker's guide, a pipe maker's testing rules and two state pool codes. We also looked at what working pool pros say about these jobs.
Key Takeaways
- Follow the water. Pump, filter, heater, then the chlorinator or feeder. Pentair puts chemical feeders downstream of the heater, with a check valve between them.[2]PentairMasterTemp Pool and Spa Heater Installation and User’s Guide. Plumbing, valves, chemical feeder and winterizing sections.pentair.com
- Give the pump straight pipe. Pentair wants 5 pipe diameters of straight pipe before the pump inlet. That is 10 inches on 2 inch pipe.[1]PentairIntelliFlo3 VSF and IntelliPro3 VSF Installation and Maintenance Guide. Plumbing and Fittings, and Valves sections.pentair.com
- Wait out the cure. Weld-On lists 30 minutes before pressurizing 1.5 to 2 inch joints at 60 to 100 degrees, up to 160 psi. Damp weather adds 50 percent.[6]Weld-On (IPS)Solvent Welding Guide, Rev. 01-24-USA. Joining procedure, repairs, cautions, and the set and cure time tables on page 18.weldon.com
- Test with water, not air. Pipe and cement makers warn that compressed air can make plastic pipe fail with explosive force.[6]Weld-On (IPS)Solvent Welding Guide, Rev. 01-24-USA. Joining procedure, repairs, cautions, and the set and cure time tables on page 18.weldon.com[7]Charlotte PipeThe Dangers of Air Testing PVC, CPVC and ABS Plumbing Systems, read November 26, 2026.charlottepipe.com
- Never go past the weakest part. Many filters are rated to 50 psi. Hayward says never test the system above 50 psi.[4]PentairClean and Clear Plus Cartridge Filter Installation and User’s Guide, 2025 edition. Pressure Tests section.pentair.com[5]HaywardSuper Pump Series Owner’s Manual, IS26001 Rev-B. Safety warnings on test pressure, compressed air and test plugs.hayward.com
- A split nut buys time. It saves a callback. But if the pipe is pulling the union out of line, it will crack again.
When a pad needs a replumb, not a patch
Most replumbs start as a small call. A pump swap. A leaky union. A salt cell that won't fit. Then you see the rest of the pad. Here are the signs that patching will cost the customer more in the long run:
- The pump cannot come out. The motor sits against a wall, or pipe runs right over the lid. You cannot pull the basket or get a camera down the line.
- Hard 90s stacked at the pump. A valve or elbow sits right on the pump inlet with no straight pipe.
- No unions. Every part is glued in. Any future repair means cutting.
- Old repair on top of old repair. Lots of couplings, bulging glue, tape, putty or flex pipe at the pad.
- Things in the wrong order. The chlorinator feeds into the heater, or a check valve sits on the wrong side.
- It will not hold prime. Air leaks at old joints, valves or unions.
A common mistake is to quote only the part you were called for. Then the next leak is "your" leak. Photograph the whole pad before you touch it. Write down what you found. Our guide on taking over another contractor's repair covers how to record a pad like this and protect yourself.
Pros do not agree on every point. Some want every pad torn out. Others say a pad that works, primes and does not leak is a job done, even if it is not pretty. The fair test is simple. Can the next tech service every part? Does the pump get the pipe it needs? Is each part in the order its manual asks for? If yes, it may not need a full replumb.
The right layout, in order
Water leaves the pool, goes through the pump, then the filter, then the heater, then the chlorinator, then back to the pool. Each manual adds a few rules. The table pulls them together.
| Spot on the pad | What the manual asks for |
|---|---|
| Suction side, before the pump | Valves, elbows or tees at least 5 pipe diameters from the inlet. Suction pipe the same size as the return or bigger. No 90 right on the pump.[1]PentairIntelliFlo3 VSF and IntelliPro3 VSF Installation and Maintenance Guide. Plumbing and Fittings, and Valves sections.pentair.com |
| Pump | Valves on both the suction and return lines when the pump sits below the water. A check valve on the return when there is a lot of height after the pump.[1]PentairIntelliFlo3 VSF and IntelliPro3 VSF Installation and Maintenance Guide. Plumbing and Fittings, and Valves sections.pentair.com |
| Filter | Between the pump and the heater. Many filters are rated to 50 psi, so nothing on the pad should push past that.[2]PentairMasterTemp Pool and Spa Heater Installation and User’s Guide. Plumbing, valves, chemical feeder and winterizing sections.pentair.com[4]PentairClean and Clear Plus Cartridge Filter Installation and User’s Guide, 2025 edition. Pressure Tests section.pentair.com |
| Heater | No valve that can shut off flow through the heater. Use a diverter to switch pool and spa. Add a bypass if flow is too high for the heater.[2]PentairMasterTemp Pool and Spa Heater Installation and User’s Guide. Plumbing, valves, chemical feeder and winterizing sections.pentair.com |
| Check valve | A chemical-resistant check valve between the heater and any chlorinator or feeder.[2]PentairMasterTemp Pool and Spa Heater Installation and User’s Guide. Plumbing, valves, chemical feeder and winterizing sections.pentair.com |
| Salt cell or feeder (last) | After the heater and lower than the heater outlet. Pentair wants its cell at least 3 feet from the heater outlet, with 12 to 18 inches of straight pipe before the cell. An inline tab feeder goes after the cell.[2]PentairMasterTemp Pool and Spa Heater Installation and User’s Guide. Plumbing, valves, chemical feeder and winterizing sections.pentair.com[3]PentairIntelliChlor Salt Chlorine Generator Installation and User’s Guide, models IC15 to IC60. Plumbing diagrams and cell installation notes.pentair.com |
Those are Pentair's rules for Pentair parts. Other brands are close but not the same. Pull the manual for each piece on the pad before you cut.
Straight pipe, sweeps and 45s
The pump rule is the one most pads break. Pentair says valves, elbows and tees on the suction side should sit at least 5 times the pipe size from the inlet. On 2 inch pipe, that is 10 inches of straight run. Pentair says this helps the pump prime faster and last longer. It also says not to put a 90 right on the pump inlet or outlet.[1]PentairIntelliFlo3 VSF and IntelliPro3 VSF Installation and Maintenance Guide. Plumbing and Fittings, and Valves sections.pentair.com
When the pad is tight, many pros turn the pump at an angle and use a pair of 45s to get the straight run. Others raise the pump on a block so the pipe lines up. Pros commonly prefer sweep 90s to hard 90s and street 90s, and they try to use fewer fittings overall. You can check the friction cost of each fitting with our pipe friction loss calculator.
“Agreed. I’ve been using sweeps on every new piece I install. Their old filter consistently ran at 20-22 on a fresh element. I’m able to move more water at a lower pressure now.”
Plan the service room, too. Leave room above the pump lid to pull the basket. Leave room to slide the motor out. Keep the heater's service panels off the wall. Do not block an electrical panel door. Then think about the next person on the pad, who is often you.
Where the check valve goes
Check valves cause more arguments than any other part of the pad. Here is what the manual says, and what pros argue about.
Between the heater and the chlorinator. Pentair's MasterTemp manual says to put a chlorinator downstream of the heater and lower than the heater outlet. It says to add a corrosion-resistant check valve between them. The goal is to stop strong chlorine from draining back to the heater once the pump shuts off.[2]PentairMasterTemp Pool and Spa Heater Installation and User’s Guide. Plumbing, valves, chemical feeder and winterizing sections.pentair.com Some pros say a salt cell stops making chlorine when flow stops, so it does not need one. Others have seen heater warranty claims go badly without one. The part costs little next to a heat exchanger. Most pros put one in. Our guide to heater warranty denials covers how claims get judged.
On the return. Pentair says to add a check valve on the return when there is a lot of height in the plumbing after the pump.[1]PentairIntelliFlo3 VSF and IntelliPro3 VSF Installation and Maintenance Guide. Plumbing and Fittings, and Valves sections.pentair.com
On the suction side. Many pros avoid this. They say a suction check valve restricts flow, clogs with leaves and hides air leaks. Some use one to help a pump above the water hold prime. If you find one, ask why it is there before you move it.
Unions: where and how
Put a union on every part you will ever pull: pump, filter, heater, cell and valves. Then a pump swap is a wrench job, not a cutting job. Use the union made for that part. Many maker unions use their own threads, so a generic nut may not fit.
Line the pipe up before you tighten a union. A union that is pulled to one side will crack. So will one that carries the weight of pipe, gets stepped on, or shakes from a heater. Support the pipe going in and out of each part. Do not let the union hold up the plumbing.
“All I can think of is the unions may be prone to cracking as the pad sinks and the heater may not sink at the exact same angle.”
Leave a few inches of pipe on each side of every valve and union. That gives the next repair room to cut and glue.
“I hate valve installs like that. You have to do a lot of repiping when they go bad because the fittings are right up against the valve.”
Which PVC cement and primer to use
Pros have strong opinions on brands. Weld-On, Oatey and Christy's all have fans. The bigger choice is the body of the cement and how you use it. Weld-On's guide lists regular-bodied cement for pipe up to 4 inches, medium-bodied up to 6 inches and heavy-bodied up to 12 inches. It also sells pool cements and specialty cements for wet jobs and flex pipe.[6]Weld-On (IPS)Solvent Welding Guide, Rev. 01-24-USA. Joining procedure, repairs, cautions, and the set and cure time tables on page 18.weldon.com Many pros keep a medium or heavy clear or gray on the truck for pad work.
The steps from Weld-On's guide are the same for any brand:[6]Weld-On (IPS)Solvent Welding Guide, Rev. 01-24-USA. Joining procedure, repairs, cautions, and the set and cure time tables on page 18.weldon.com
- Cut the pipe square. Remove burrs inside and out, and bevel the end.
- Wipe the pipe and fitting clean and dry. Water slows the cure. Dirt and oil can stop a good weld.
- Mark the socket depth on the pipe. Dry fit it. It should not be loose.
- Prime the socket, then the pipe, then the socket again. Do not let primer run down the pipe.
- Put a thick coat of cement on the pipe and a medium coat in the socket.
- Push the pipe all the way in, in one move. Hold it for at least 30 seconds.
- Look for a full bead of cement around the joint. Wipe off the extra.
Two more rules from the guide matter on a pad. Do not let primer or cement run into a valve. It can damage the parts inside. And never thin old cement with primer or cleaner.[6]Weld-On (IPS)Solvent Welding Guide, Rev. 01-24-USA. Joining procedure, repairs, cautions, and the set and cure time tables on page 18.weldon.com
Clear or purple primer? Clear looks cleaner above ground. Colored primer shows an inspector, or a boss, that every joint was primed. If an inspector will see the work, ask what they want before you start. Paint exposed PVC when the job is done, since pros commonly report sun damage on bare pipe.
How long before you can run water
This is the question every tech asks while the customer stands there. The answer depends on pipe size, temperature, humidity and pressure. Weld-On splits it into two times. The set time is when you can carefully handle the joint. The cure time is when you can pressurize it.[6]Weld-On (IPS)Solvent Welding Guide, Rev. 01-24-USA. Joining procedure, repairs, cautions, and the set and cure time tables on page 18.weldon.com
| Temperature | Set time, 1.5 to 2 inch | Cure time, 1.5 to 2 inch, up to 160 psi | Cure time, 2.5 to 8 inch, up to 160 psi |
|---|---|---|---|
| 60 to 100°F | 5 minutes | 30 minutes | 1.5 hours |
| 40 to 60°F | 10 minutes | 45 minutes | 4 hours |
| 0 to 40°F | 15 minutes | 1 hour | 72 hours |
Source: Weld-On's average set and cure schedules, at 60 percent humidity or less.[6]Weld-On (IPS)Solvent Welding Guide, Rev. 01-24-USA. Joining procedure, repairs, cautions, and the set and cure time tables on page 18.weldon.com In damp or humid weather, Weld-On says to allow 50 percent more time. It also says these are lab numbers, and field results can vary a lot.[6]Weld-On (IPS)Solvent Welding Guide, Rev. 01-24-USA. Joining procedure, repairs, cautions, and the set and cure time tables on page 18.weldon.com Other brands have their own charts, so use the chart for the cement in your hand.
Notice the jump for bigger pipe in the cold. A 2.5 inch joint at 35 degrees needs days, not minutes. On a winter job, plan to come back. Do not fire up the pump on fresh joints to save a trip.
Speed comes with practice. The first replumb takes a long time for everyone.
“Now I could go out there and probably knock it out in 15 minutes. Get it painted, it looks professional, just be done. But at the time it took me an hour and a half or two hours because I was so nervous.”
Fixing a cracked union without a full replumb
A union nut cracks on a weekly stop, and there is no room to cut. You have a few choices. Each one has a cost.
- Swap the nut. If the threads and tailpiece are fine, a new nut from the maker is the cleanest fix.
- Two-piece split nut. It snaps around the tailpiece with no cutting. Many pros carry the common sizes. It turns a callback into a short fix on the spot. Many pros also call it a short-term fix, and many sizes and brands have no split nut at all.
- Remove the old tailpiece. Some pros warm the old fitting with a heat gun until it goes soft, then pry it out. Others use a fitting reamer to cut it out of the socket. Then they glue in a new union. This takes skill. Practice on scrap first. Weld-On warns that cement vapors are flammable and can linger around fresh joints, so keep heat and sparks away from wet cement.[6]Weld-On (IPS)Solvent Welding Guide, Rev. 01-24-USA. Joining procedure, repairs, cautions, and the set and cure time tables on page 18.weldon.com
- Fitting extender. It goes over or inside a cut fitting to save a tee or valve. An inside extender makes the pipe smaller and cuts flow. Tell the customer that.
- Cut and replumb that section. It is the slowest choice, and the one least likely to come back.
Before you choose, ask why it cracked. A pipe pulling the union out of line, a pad that settled or a heater that shakes will crack the new nut too. Fix the cause or the customer pays twice.
Skip the glue, tape and sealant patches on a cracked nut. Weld-On says that after years of looking at failed joints, most attempts to repair a leaking joint do not work. In most cases, it says, cutting out the bad joint and replacing it is the better deal.[6]Weld-On (IPS)Solvent Welding Guide, Rev. 01-24-USA. Joining procedure, repairs, cautions, and the set and cure time tables on page 18.weldon.com
How to pressure test pool lines
A pressure test proves the lines hold. Builders run them before the deck goes in. Repair techs run them to find a broken line or to check a repair. Some builders even leave a hose bib on the pad for it.
“Company I worked for would put them on all new builds in between the pump and filter somewhere. Used to pressure the system before plaster. I’ve used them before to pressure test things way down the road as well.”
Use water, not compressed air. Weld-On says its PVC cements should not be used in a system being tested with compressed air or gas. Compressed air stores a lot of energy, and a failure can be violent.[6]Weld-On (IPS)Solvent Welding Guide, Rev. 01-24-USA. Joining procedure, repairs, cautions, and the set and cure time tables on page 18.weldon.com Charlotte Pipe says it does not recommend air testing plastic pipe under any condition. It also says water testing finds leaks better, because air pressure changes with the temperature.[7]Charlotte PipeThe Dangers of Air Testing PVC, CPVC and ABS Plumbing Systems, read November 26, 2026.charlottepipe.com Hayward says not to purge the system with compressed air. For blowing out lines it says to use only a low pressure blower, below 5 psi.[5]HaywardSuper Pump Series Owner’s Manual, IS26001 Rev-B. Safety warnings on test pressure, compressed air and test plugs.hayward.com
What pressure? There is no one number for every job. Your local code sets it. Two examples:
- Arizona has a licensed contractor test new circulation piping at 25 psi for at least 30 minutes, before the deck is poured.[8]Arizona Administrative CodeR18-5-224, Piping and Fittings, read November 26, 2026.law.cornell.edu
- Wisconsin tests piping installed on site at 25 psi for at least one hour.[9]Wisconsin Administrative CodeSPS 390.14, Circulation systems, testing of onsite piping, read November 26, 2026.docs.legis.wisconsin.gov
Check your own state and city code before you pick a number. Old buried pipe is a different case from new pipe. If you are not sure what an old line can take, do not guess. Bring in a leak detection pro with the right gear.
Never go past the weakest part. Pentair's filter guide says the filter's top rating is 50 psi. It says to keep any pressure test below the rating of every part in the system.[4]PentairClean and Clear Plus Cartridge Filter Installation and User’s Guide, 2025 edition. Pressure Tests section.pentair.com Hayward says never test the system above 50 psi.[5]HaywardSuper Pump Series Owner’s Manual, IS26001 Rev-B. Safety warnings on test pressure, compressed air and test plugs.hayward.com The safe move is to isolate the equipment and test only the lines.
Keep people back. Pentair says to keep the test as short as the code allows. Keep people away from the system while it is under test. Put up warning signs and a barrier. Lock the equipment room door.[4]PentairClean and Clear Plus Cartridge Filter Installation and User’s Guide, 2025 edition. Pressure Tests section.pentair.com
Wait for the cure, then clean up. Let new joints reach full cure before you test them.[6]Weld-On (IPS)Solvent Welding Guide, Rev. 01-24-USA. Joining procedure, repairs, cautions, and the set and cure time tables on page 18.weldon.com When you finish, pull every test plug. Hayward warns that test plugs left in suction outlets raise the risk of suction entrapment.[5]HaywardSuper Pump Series Owner’s Manual, IS26001 Rev-B. Safety warnings on test pressure, compressed air and test plugs.hayward.com
The cracked skimmer guide covers testing a skimmer before you choose a repair.
A broken or leaking pipe underground
Most underground repairs follow the same path. First, prove the leak and find it. Use a bucket test, a dye test, then a pressure test of each line. Listening gear or a camera narrows it down. Our bucket test calculator helps sort a real leak from evaporation.
Then you dig, or cut the deck. You expose the break, cut out the bad section, and glue in new pipe with couplings. Water in the trench is the problem. Pros commonly lower the water, plug the line from the pool side, or use a test plug or drain bladder to stop flow while they glue. A cement made for wet work helps, but read its label first. Weld-On sells a cement for wet conditions.[6]Weld-On (IPS)Solvent Welding Guide, Rev. 01-24-USA. Joining procedure, repairs, cautions, and the set and cure time tables on page 18.weldon.com
Many pros will not trust flex pipe underground. They report it collapsing, swelling or getting chewed by bugs over the years. When a repair finds old flex, many replace a longer run with rigid PVC.
The hard part is not the glue. It is what you cannot see. Tell the customer up front that the price can change once the ground is open.
“I do have a really good concrete guy, so if it is under concrete, I can take it on, but there are a lot of unknowns when it’s underground that can be a little risky if you wanna do the repair for it. But letting the client know that ahead of time is good communication.”
Pressure test the line again after the repair, once the joints cure. Then backfill. A line that leaks under a new patch of concrete is the worst callback in the trade.
How to price a replumb or pipe repair
Replumbs and line repairs are time jobs with a lot of unknowns. There is no good national price for them yet. Most pros build the quote from their own rates. On poolrates.fyi, pros' service call fees average about $162, their hourly repair rate averages about $139, and their parts markup averages about 1.65 times cost.[10]poolrates.fyiRepair prices pool pros shared, January to October 2026: service call fee (10 prices), hourly repair rate (12 prices) and parts markup (12 pros). Averages of the values.poolrates.fyi
For a pad replumb, pros commonly quote labor in the range of several hundred dollars up to about $1,200, plus parts. A replumb with a new pump, filter or salt system lands in the thousands. Price what you see on your own pad, not someone else's.
A few habits keep these jobs from losing money:
- Quote the pad, not the part. If the pump swap needs a new suction run, say so in the first quote. Customers do not like a surprise after you start.
- Give options. A split nut today, or a replumb that fixes the cause. Write down which one they chose.
- Charge for digging as its own line. Concrete work, digging and backfill can run longer than the plumbing.
- Price the return trip. Cold weather can mean a long cure, a second visit, or both.
- Stock the truck. Common unions, split nuts, couplings, 45s, sweeps and a fitting reamer turn many calls into one visit.
Our one-time job calculator helps build the number. The leak cost calculator shows a customer what a slow leak costs them while they decide.
Before you leave the pad
- Every joint has passed its cure time, and the system ran with no drips.
- The pump primes, and the filter pressure looks right for the pump speed.
- The heater, cell and flow switch all see flow.
- Every test plug is out, and every valve is set where it belongs.
- Exposed PVC is painted, or the customer knows it should be.
- You took after photos of the whole pad, the labels and each union.
Those photos matter. A clear record of how you left the pad settles arguments when the next leak shows up. For freeze-season repairs, our freeze damage guide covers what breaks first and how to document it. Our warranty guide covers what makers ask for when a part fails.
Sources
- [1]Pentair, IntelliFlo3 VSF and IntelliPro3 VSF Installation and Maintenance Guide. Plumbing and Fittings, and Valves sections. pentair.com (PDF)
- [2]Pentair, MasterTemp Pool and Spa Heater Installation and User’s Guide. Plumbing, valves, chemical feeder and winterizing sections. pentair.com (PDF)
- [3]Pentair, IntelliChlor Salt Chlorine Generator Installation and User’s Guide, models IC15 to IC60. Plumbing diagrams and cell installation notes. pentair.com (PDF)
- [4]Pentair, Clean and Clear Plus Cartridge Filter Installation and User’s Guide, 2025 edition. Pressure Tests section. pentair.com (PDF)
- [5]Hayward, Super Pump Series Owner’s Manual, IS26001 Rev-B. Safety warnings on test pressure, compressed air and test plugs. hayward.com (PDF)
- [6]Weld-On (IPS), Solvent Welding Guide, Rev. 01-24-USA. Joining procedure, repairs, cautions, and the set and cure time tables on page 18. weldon.com (PDF)
- [7]Charlotte Pipe, The Dangers of Air Testing PVC, CPVC and ABS Plumbing Systems, read November 26, 2026. charlottepipe.com
- [8]Arizona Administrative Code, R18-5-224, Piping and Fittings, read November 26, 2026. law.cornell.edu
- [9]Wisconsin Administrative Code, SPS 390.14, Circulation systems, testing of onsite piping, read November 26, 2026. docs.legis.wisconsin.gov
- [10]poolrates.fyi, Repair prices pool pros shared, January to October 2026: service call fee (10 prices), hourly repair rate (12 prices) and parts markup (12 pros). Averages of the values. poolrates.fyi