DEL ozone generator family for supplemental pool sanitation, installed into the main return after other pool equipment.
| Electrical | |
|---|---|
| Voltage | 120/240V |
| Frequency | 50/60 Hz |
| Current Draw | 0.10A for Ozone 25, 0.24A for Ozone 50, 0.31A for Ozone 100 |
| Breaker Size | Manual calls for GFCI protection if on an independent supply. |
| Physical | |
| Plumbing Connection | Venturi injector introduces ozone gas into the main return after all other equipment. |
| Vertical Clearance | Install ozone generator at least 1 ft above maximum water level. |
| Horizontal Clearance | Install at least 5 ft from pool wall. |
| Part | Part Number | Description |
|---|---|---|
| Ozone Module Subassembly | Service manual upgrade procedure replaces the bracket with ozone modules, power supplies, and manifold. | |
| Ozone Outlet Manifold | Service manual reconnects the new manifold tube to the ozone outlet barb with a new tubing clamp. | |
| Tubing Clamp | Service manual calls for a new tubing clamp when reconnecting the ozone outlet manifold. |