Run the filter pump from before the air hits freezing until the air is back above freezing, and open every valve so water moves in every pipe. If the power fails, switch off the pool breaker and drain the equipment.
That is the whole plan for a pool that stays open all winter, which is how pools are run in Texas, the Gulf states, Arizona and most of the Southeast. The rest of this post covers the parts that trip people up, from freeze protection that is not really on to a dead power line.
This post is about the equipment. If you run a route, the business side is in the hard-freeze playbook for pool service companies.
Key Takeaways
- Moving water is the plan. Pentair says water that is moving is slower to freeze, so keep the pump on through the cold.[1]PentairWinter Weather Pool Protection page, read November 24, 2026. Steps for a power outage and for severe weather.pentair.com
- Freeze protection is a helper. It turns the pump on near freezing, but Jandy says it is only for short freezes and it is no promise.[4]JandyAquaLink RS Owner's Manual, 6593 Rev O. Section 7.4, Freeze Protection Menu, and Important Information on Freeze Protection.jandy.com
- Check it before the cold. Each brand has its own trip point, and some pads have no freeze sensor at all.[2]PentairIntelliCenter Control System User's Guide, P/N 522990 Rev. F. Freeze Protection, Delays and Heater Operation During Freeze Protection.pentair.com[5]HaywardOmniLogic Installation Manual, 092472 Rev L. Freeze Protection Enabled, Freeze Protection Temperature and Freeze Protect Speed settings.hayward.com[6]IntermaticPF1100 Series Freeze Protection Control, Installation, Operation and Service Manual for models PF1102T and PF1102MT.Intermatic manual
- A pump is not a freeze guard. The cold mode built into a variable speed pump guards the pump and not the pipes.[7]PentairIntelliFlo3 VSF and IntelliPro3 VSF Installation and Maintenance Guide, P/N 356231 Rev. E. Default Settings, Thermal Mode and Winterizing.pentair.com[8]HaywardTriStar VS 950 Owner's Manual, IS32950VSP Rev B. Low Temp Operation note and section 8, Maintenance and Winterization.Hayward manual
- Leave the heater out of it. Pentair and Raypak both say not to use a heater for freeze protection.[10]PentairMasterTemp Pool and Spa Heater Installation and User's Guide. Safety warnings and the Maintenance section on cold weather and winterizing.pentair.com[11]RaypakDigital and Millivolt Gas Pool Heater Models 206A to 406A, Installation and Operation Manual, P/N 241236. Important Freeze Information.raypak.com
- No power means drain. Turn the breaker off, take the lids off, open the relief valve and pull the plugs.[1]PentairWinter Weather Pool Protection page, read November 24, 2026. Steps for a power outage and for severe weather.pentair.com
The short answer for tonight
Work down this list in order, and read further down for the reason behind each step.
- Fill the pool until the water reaches the middle of the skimmer.[13]Leslie'sWinter Freeze: A How-To When Responding to Freezing Weather Conditions, read November 24, 2026.lesliespool.com
- Clean the baskets and the filter so you have strong flow all night.
- Set the pump to run 24 hours, even if the pad has freeze protection. Pentair pump guides say to run the filter gear all night when a short freeze is coming.[7]PentairIntelliFlo3 VSF and IntelliPro3 VSF Installation and Maintenance Guide, P/N 356231 Rev. E. Default Settings, Thermal Mode and Winterizing.pentair.com
- Open the valves so water moves through the skimmers, the main drain, the returns, the spa and every feature that still holds water.
- Turn the heater off, but keep water flowing through it.
- Keep sleet off the pad without wrapping a running motor.
- Find the drain plugs in daylight and put the right tool next to them.
- Check the pool before bed and at sunrise to see that water is still moving at the returns.
The Weather Service sends a Freeze Watch when a hard cold spell may hit in the next 24 to 36 hours, and that is your signal to do the list.[14]National Weather ServiceCold Weather Watches, Warnings and Advisories page, read November 24, 2026. Freeze Watch and Freeze Warning.weather.gov
Why moving water protects the equipment
Water grows when it turns to ice. Inside a pump, a filter or a pipe it has no room to grow, so the part cracks. Pentair puts it plainly when it says frozen pool water expands and needs a place to go.[1]PentairWinter Weather Pool Protection page, read November 24, 2026. Steps for a power outage and for severe weather.pentair.com
Moving water fights this in two ways. Ice has a hard time forming in a stream, and the pump keeps pulling water from deep in the pool, where it is warmer than the air. That water warms the parts on the pad a little as it flows through them.
The weak spots are the parts that sit out in the air, like the pump, the filter, the heater, the salt cell, the valves and the short pipes that stand up out of the ground. Pipes buried in the yard are safer in a short Southern freeze, because the ground stays warmer than the air.
“Here in N. California we just have to set the equipment to run at night and make sure that all of the solar systems are drained. It has gotten cold enough to freeze plumbing a few times but it's rare.”
There is a limit, because moving water can still freeze if it gets cold enough for long enough. Jandy says in its manual that freeze protection is for short freezes, and that for a long freeze or a power outage the pool should be shut down and drained.[4]JandyAquaLink RS Owner's Manual, 6593 Rev O. Section 7.4, Freeze Protection Menu, and Important Information on Freeze Protection.jandy.com A pool that runs all winter is a bet that the cold will be short and the power will stay on.
What built-in freeze protection does
Freeze protection is simple. An air sensor sits at the pad, and when the air gets close to freezing the controller turns the pump on and keeps it on until the air warms up. It does not heat the water, and it does not work with the power off.
Each brand trips at its own number, so here is what the manuals say.
| Control | When it turns on | What it runs |
|---|---|---|
| Pentair IntelliCenter | Air near 36°F[2]PentairIntelliCenter Control System User's Guide, P/N 522990 Rev. F. Freeze Protection, Delays and Heater Operation During Freeze Protection.pentair.com | Every circuit you set to freeze protection, with the pool and spa valves trading places |
| Pentair EasyTouch | Air below 36°F on one page of the guide and 35°F on another[3]PentairEasyTouch Control System User's Guide, 8 and 4 for Pool and Spa. Freeze Protection, Circuit Functions and IntelliChlor sections.pentair.com | Circuits set to Freeze: Yes for 15 minutes each, with pool and spa swapping every 15 minutes |
| Jandy AquaLink RS | You pick 34°F to 42°F, and it ships at 38°F[4]JandyAquaLink RS Owner's Manual, 6593 Rev O. Section 7.4, Freeze Protection Menu, and Important Information on Freeze Protection.jandy.com | The filter pump always, and other gear only if you add it |
| Hayward OmniLogic | You pick 33°F to 42°F, and it ships at 38°F[5]HaywardOmniLogic Installation Manual, 092472 Rev L. Freeze Protection Enabled, Freeze Protection Temperature and Freeze Protect Speed settings.hayward.com | The filter pump if turned on, with pool and spa valves swapping every 30 minutes |
| Intermatic PF1102T timer | A dial set from 33°F to 42°F[6]IntermaticPF1100 Series Freeze Protection Control, Installation, Operation and Service Manual for models PF1102T and PF1102MT.Intermatic manual | The filter pump only |
Note what is missing from that list. Lights, cleaner pumps, waterfall pumps and spa jets only come on if someone set them to, and none of these systems can do a thing in a blackout.
“And that word, those words freeze protection always lends itself to freeze guarantee to some people. They hear that and they think it's a guarantee of some sort.”
How to confirm freeze protection is on
Do not guess about this. Look at each of these points before the cold comes.
- Is there an air sensor? Hayward says the air sensor must be in place for freeze protection to work.[5]HaywardOmniLogic Installation Manual, 092472 Rev L. Freeze Protection Enabled, Freeze Protection Temperature and Freeze Protect Speed settings.hayward.com It should sit outside in open air, because a sensor in a shed, under a cover or in the sun reads warm and leaves the pump off.
- Is the pump circuit set to freeze? On EasyTouch the pool and spa are set to yes from the factory, and every other circuit starts at no.[3]PentairEasyTouch Control System User's Guide, 8 and 4 for Pool and Spa. Freeze Protection, Circuit Functions and IntelliChlor sections.pentair.com On AquaLink the filter pump is always on the list and the rest are up to you.[4]JandyAquaLink RS Owner's Manual, 6593 Rev O. Section 7.4, Freeze Protection Menu, and Important Information on Freeze Protection.jandy.com On OmniLogic you answer yes or no for each pump.[5]HaywardOmniLogic Installation Manual, 092472 Rev L. Freeze Protection Enabled, Freeze Protection Temperature and Freeze Protect Speed settings.hayward.com
- Is the trip point where you want it? Jandy and Hayward let you move it, and a higher number turns the pump on sooner.[4]JandyAquaLink RS Owner's Manual, 6593 Rev O. Section 7.4, Freeze Protection Menu, and Important Information on Freeze Protection.jandy.com[5]HaywardOmniLogic Installation Manual, 092472 Rev L. Freeze Protection Enabled, Freeze Protection Temperature and Freeze Protect Speed settings.hayward.com
- How long is each cycle? IntelliCenter has a Freeze Cycle Time that you can set from 5 to 60 minutes, and it ships at 5.[2]PentairIntelliCenter Control System User's Guide, P/N 522990 Rev. F. Freeze Protection, Delays and Heater Operation During Freeze Protection.pentair.com
- Is the panel in Auto? Pentair notes that an IntelliFlo pump will stop when EasyTouch is in Service mode, so check the mode before you leave.[3]PentairEasyTouch Control System User's Guide, 8 and 4 for Pool and Spa. Freeze Protection, Circuit Functions and IntelliChlor sections.pentair.com
- Does the screen agree? When it is working, IntelliCenter shows the words Freeze Protect Active on the home screen.[2]PentairIntelliCenter Control System User's Guide, P/N 522990 Rev. F. Freeze Protection, Delays and Heater Operation During Freeze Protection.pentair.com
We have step by step pages for the big three: IntelliCenter freeze protection, EasyTouch freeze protection and AquaLink RS freeze protection.
Even when it all checks out, many pros still set the pump to run around the clock for a hard freeze. Sensors fail and a stuck valve can stop the whole system, so a manual schedule takes those risks out of play for the price of a few days of power.
Pads with no freeze sensor, or a pump on a plain timer
Lots of pools have no control panel. They have a variable speed pump with its own keypad, or an older pump on a clock timer, and these pads need the most care.
A variable speed pump on its own
Many of these pumps have a cold mode, which Pentair calls Thermal Mode. On the IntelliFlo3 it ships turned on and set to 40°F and 20 percent speed.[7]PentairIntelliFlo3 VSF and IntelliPro3 VSF Installation and Maintenance Guide, P/N 356231 Rev. E. Default Settings, Thermal Mode and Winterizing.pentair.com That sounds like freeze protection, but it is not.
The sensor is inside the drive on top of the motor, so it reads the drive and not the air. Pentair says not to count on it alone to protect the filter system.[7]PentairIntelliFlo3 VSF and IntelliPro3 VSF Installation and Maintenance Guide, P/N 356231 Rev. E. Default Settings, Thermal Mode and Winterizing.pentair.com Hayward says its Low Temp Operation is not meant to protect the pump, the plumbing or the pool from freezing, and that it shuts off when the pump is run by an outside controller.[8]HaywardTriStar VS 950 Owner's Manual, IS32950VSP Rev B. Low Temp Operation note and section 8, Maintenance and Winterization.Hayward manual
“Variable speed motors all have freeze protection in them. But in all honesty, it's device protection.”
Federal rules also hold it back. A pump with a freeze control must ship with it off, or set to start at 40°F or lower, run no more than one hour before it checks again, and spin at no more than half speed.[9]U.S. Department of Energy10 CFR 431.465(h), energy conservation standards for dedicated-purpose pool pumps with freeze protection controls.law.cornell.edu Those are factory settings that you are free to change.
So on a freeze night, program the pump yourself with one schedule that runs 24 hours. Pick a speed that gives strong flow at every return and every feature. No manual gives one right number, but most pros use a middle or high speed for a hard freeze and not the slow speed they use to save power.
A pump on a clock timer
A plain timer knows the time, but it does not know the cold. If the pump shuts off at 6 p.m., it stays off all night. Use the manual on setting of the timer so the pump keeps running, and check that it is still on before bed.
Some timers have a freeze dial built in. The Intermatic PF1102T turns the filter pump on when the air at the timer drops below the dial setting.[6]IntermaticPF1100 Series Freeze Protection Control, Installation, Operation and Service Manual for models PF1102T and PF1102MT.Intermatic manual It reads the air where the box hangs, and Intermatic says it does not take the place of insulation, covers or upkeep.[6]IntermaticPF1100 Series Freeze Protection Control, Installation, Operation and Service Manual for models PF1102T and PF1102MT.Intermatic manual
These timers get tricky with a variable speed pump, because the timer can send power but cannot tell the pump what speed to run. If the pump's own schedule says off, the pump may sit there with power and not move water. The safe move is to give the pump a 24 hour schedule. If you want a timer or a sensor wired in to run the pump for you, hire a licensed pro for that job.
Water features, spa, cleaner lines, heater and salt cell
Water features
A waterfall, a bubbler or a deck jet is a pipe that runs high and close to the cold air, and water that sits in it can freeze. You have two choices, which are to run it or to drain it.
For a short freeze, most pros run every feature that still holds water. A feature with its own pump needs that pump on too, since the main pump will not move water through it. On OmniLogic each feature pump has its own freeze setting, and on EasyTouch each circuit does, so check that they are set to yes.[5]HaywardOmniLogic Installation Manual, 092472 Rev L. Freeze Protection Enabled, Freeze Protection Temperature and Freeze Protect Speed settings.hayward.com[3]PentairEasyTouch Control System User's Guide, 8 and 4 for Pool and Spa. Freeze Protection, Circuit Functions and IntelliChlor sections.pentair.com
For a long, hard freeze, pros split. Falling water chills the pool fast, and ice can build on the rocks until it blocks the flow, so many pros drain and shut down features ahead of a long freeze. If a feature is drained, leave it off.
The spa
On a pool and spa combo, the controller swaps the valves back and forth so both sides get flow. EasyTouch does it every 15 minutes and OmniLogic does it every 30.[3]PentairEasyTouch Control System User's Guide, 8 and 4 for Pool and Spa. Freeze Protection, Circuit Functions and IntelliChlor sections.pentair.com[5]HaywardOmniLogic Installation Manual, 092472 Rev L. Freeze Protection Enabled, Freeze Protection Temperature and Freeze Protect Speed settings.hayward.com That is normal, and so is water spilling from the spa into the pool.
Using the spa on a freeze night has a catch. Jandy warns that turning on the spa overrides freeze protection, so water stops moving to gear that is not part of the spa, like a cleaner pump.[4]JandyAquaLink RS Owner's Manual, 6593 Rev O. Section 7.4, Freeze Protection Menu, and Important Information on Freeze Protection.jandy.com IntelliCenter limits this with a Spa Freeze Override Time that you can set from 0 to 240 minutes.[2]PentairIntelliCenter Control System User's Guide, P/N 522990 Rev. F. Freeze Protection, Delays and Heater Operation During Freeze Protection.pentair.com If someone soaks, switch back to pool mode when they are done.
Cleaner lines
A pressure cleaner has its own line and a small booster pump. Pentair says the booster pump most often does not need its own freeze setting, since it gets flow from the filter pump, as long as the pool circuit is protected.[3]PentairEasyTouch Control System User's Guide, 8 and 4 for Pool and Spa. Freeze Protection, Circuit Functions and IntelliChlor sections.pentair.com Check your own setup, because a booster pump must never run dry. Leslie's says to pull an automatic cleaner out of the pool and drain it before the cold.[13]Leslie'sWinter Freeze: A How-To When Responding to Freezing Weather Conditions, read November 24, 2026.lesliespool.com
“Customers are crazy! I just had a customer accuse me of breaking her booster pump because I ran the Polaris during a freeze without the cleaner attached.”
The heater
It is tempting to fire the heater and warm the pool past the freeze, but the makers say no. Pentair says not to use the MasterTemp to guard against freezing if the water will stay under 68°F, because it makes harmful water drops inside the heater and voids the warranty.[10]PentairMasterTemp Pool and Spa Heater Installation and User's Guide. Safety warnings and the Maintenance section on cold weather and winterizing.pentair.com Raypak says not to use the heater for freeze protection, and that it has no warranty against freeze-ups.[11]RaypakDigital and Millivolt Gas Pool Heater Models 206A to 406A, Installation and Operation Manual, P/N 241236. Important Freeze Information.raypak.com
The heater still needs flow. Raypak says that from 0°F to 32°F the pump must run all the time, so leave the heater off and leave its valves open.[11]RaypakDigital and Millivolt Gas Pool Heater Models 206A to 406A, Installation and Operation Manual, P/N 241236. Important Freeze Information.raypak.com IntelliCenter will not fire the heater during freeze protection unless you turn it on by hand.[2]PentairIntelliCenter Control System User's Guide, P/N 522990 Rev. F. Freeze Protection, Delays and Heater Operation During Freeze Protection.pentair.com
The brands do not fully agree on what comes next. Pentair says to shut the heater down and winterize it when the air will drop below freezing, while Raypak allows use in short cold spells with the pump on.[10]PentairMasterTemp Pool and Spa Heater Installation and User's Guide. Safety warnings and the Maintenance section on cold weather and winterizing.pentair.com[11]RaypakDigital and Millivolt Gas Pool Heater Models 206A to 406A, Installation and Operation Manual, P/N 241236. Important Freeze Information.raypak.com Read the manual for the heater on your pad.
The salt cell
A salt cell stops on its own in cold water. The IntelliChlor shuts off near 52°F and lights its Cold Water light.[12]PentairIntelliChlor Salt Chlorine Generator Installation and User's Guide, P/N 520589 Rev. R. Temperature sensor and Winterizing.pentair.com EasyTouch and OmniLogic will not run the cell when freeze protection is the only reason the pump is on.[3]PentairEasyTouch Control System User's Guide, 8 and 4 for Pool and Spa. Freeze Protection, Circuit Functions and IntelliChlor sections.pentair.com[5]HaywardOmniLogic Installation Manual, 092472 Rev L. Freeze Protection Enabled, Freeze Protection Temperature and Freeze Protect Speed settings.hayward.com So expect no chlorine from the cell that week, and test the water and add chlorine by hand per the label if it needs it.
The cell can crack like any other part. Pentair says to protect it by running the pump the whole time, or by draining the system and taking the cell out.[12]PentairIntelliChlor Salt Chlorine Generator Installation and User's Guide, P/N 520589 Rev. R. Temperature sensor and Winterizing.pentair.com We cover the cold water lockout on Hayward cells in this AquaRite guide.
Water level, skimmers and ice on the surface
The pump can only move water it can reach. If the level drops under the skimmer mouth, the pump pulls air and stops moving water, and then the pad freezes with the pump still humming. Keep the water at the middle of the skimmer, and top it off before the freeze, since a frozen hose is no help later.[13]Leslie'sWinter Freeze: A How-To When Responding to Freezing Weather Conditions, read November 24, 2026.lesliespool.com
A skin of ice on top of the pool is common in a hard freeze, and water keeps moving under it. The danger spots are the skimmers, because flow stops if ice closes the skimmer mouth. Check them often, clear slush from the skimmer by hand, and make sure the flap door swings free.
Should you break the ice?
This is where advice splits. Pentair warns that surface ice grows and pushes on the tile until tiles chip or pop off, and its fix is to keep water flowing as long as you can.[1]PentairWinter Weather Pool Protection page, read November 24, 2026. Steps for a power outage and for severe weather.pentair.com Leslie's tells owners not to try to break up ice sheets on their own.[13]Leslie'sWinter Freeze: A How-To When Responding to Freezing Weather Conditions, read November 24, 2026.lesliespool.com Yet plenty of pros clear ice near the skimmers to keep the pump fed.
A fair middle path looks like this.
- Do not swing a hammer, a shovel or a pole at the ice, because Leslie's warns that the sharp edges of broken ice can damage pool surfaces.[13]Leslie'sWinter Freeze: A How-To When Responding to Freezing Weather Conditions, read November 24, 2026.lesliespool.com
- Do keep the skimmer mouths open by lifting out slush and loose ice with your hands or a net.
- Leave the big sheet alone and let moving water and the sun melt it.
- Never step on pool ice, and keep kids and pets away, because it will not hold.
Covering the equipment pad
A cover helps in one main way, which is that it keeps sleet and freezing rain off the pipes, lids and drain plugs. That matters if you need to pull plugs at 2 a.m. and they are under a sheet of ice.
The motor is the problem. Pentair says a motor may be covered in a storm, but never while it runs or is about to run, and never wrapped in plastic or any airtight wrap.[7]PentairIntelliFlo3 VSF and IntelliPro3 VSF Installation and Maintenance Guide, P/N 356231 Rev. E. Default Settings, Thermal Mode and Winterizing.pentair.com Hayward says not to wrap a pump in plastic film or bags.[8]HaywardTriStar VS 950 Owner's Manual, IS32950VSP Rev B. Low Temp Operation note and section 8, Maintenance and Winterization.Hayward manual A running motor needs air.
“sometimes people put blankets over their equipment we're like don't do that like it's okay.”
So build a roof and not a wrap.
- Use a tarp held up like a tent, with the motor end open to the air.
- Skip blankets and towels on the gear, because they soak up rain and freeze onto the pipes.
- Do not cover the air sensor, because a warm sensor will not start the pump.
- Do not put a heat lamp or a space heater under a tarp, since that is a fire risk next to water and power.
- Brush snow and ice off the pad if it piles up, since buried gear can trip a breaker.
If the power goes out: how to drain the equipment
No power means no flow, so now the plan flips. You want the water out of every part that sits in the air, because air cannot crack a pump.
How long can you wait? No manual gives a number, since it depends on how cold it is and how hard the wind blows. If the air is well under freezing and the power is not coming back soon, drain it, and if you are not sure, drain it anyway.
These steps come from the outage guide that Pentair publishes and from the makers' winterizing pages.[1]PentairWinter Weather Pool Protection page, read November 24, 2026. Steps for a power outage and for severe weather.pentair.com[7]PentairIntelliFlo3 VSF and IntelliPro3 VSF Installation and Maintenance Guide, P/N 356231 Rev. E. Default Settings, Thermal Mode and Winterizing.pentair.com[10]PentairMasterTemp Pool and Spa Heater Installation and User's Guide. Safety warnings and the Maintenance section on cold weather and winterizing.pentair.com
- Turn off the pool breakers so the gear cannot start on its own when power comes back, because frozen gear that starts can break.[1]PentairWinter Weather Pool Protection page, read November 24, 2026. Steps for a power outage and for severe weather.pentair.com
- Open the filter's air relief valve and stand clear until the gauge reads zero.[7]PentairIntelliFlo3 VSF and IntelliPro3 VSF Installation and Maintenance Guide, P/N 356231 Rev. E. Default Settings, Thermal Mode and Winterizing.pentair.com
- Take off the pump lid and pull both drain plugs from the pump, then put them in the pump basket so they do not get lost.[7]PentairIntelliFlo3 VSF and IntelliPro3 VSF Installation and Maintenance Guide, P/N 356231 Rev. E. Default Settings, Thermal Mode and Winterizing.pentair.com
- Pull the filter drain plug, which sits low on the tank and may need a tool. On a sand or DE filter, pull the plug at the dial valve too.[1]PentairWinter Weather Pool Protection page, read November 24, 2026. Steps for a power outage and for severe weather.pentair.com
- Drain the heater. Pentair says to pull the drain plugs next to the heater, and on a MasterTemp the drain is on the bottom of the manifold.[1]PentairWinter Weather Pool Protection page, read November 24, 2026. Steps for a power outage and for severe weather.pentair.com[10]PentairMasterTemp Pool and Spa Heater Installation and User's Guide. Safety warnings and the Maintenance section on cold weather and winterizing.pentair.com Some heaters hide the plug behind a panel, so use the manual for your model.
- Drain the small stuff by pulling the plug on a booster pump or a waterfall pump. Pentair says to take the salt cell out when the system is drained.[12]PentairIntelliChlor Salt Chlorine Generator Installation and User's Guide, P/N 520589 Rev. R. Temperature sensor and Winterizing.pentair.com
- Open as many valves as you can so no water is trapped between them.[1]PentairWinter Weather Pool Protection page, read November 24, 2026. Steps for a power outage and for severe weather.pentair.com
- Keep the rain off, since you can cover the motor now that it is off.[7]PentairIntelliFlo3 VSF and IntelliPro3 VSF Installation and Maintenance Guide, P/N 356231 Rev. E. Default Settings, Thermal Mode and Winterizing.pentair.com
Here are two cautions. Do not try to blow the lines out with a shop air compressor, because Pentair warns that high pressure air can make parts explode.[10]PentairMasterTemp Pool and Spa Heater Installation and User's Guide. Safety warnings and the Maintenance section on cold weather and winterizing.pentair.com And do not pour car antifreeze in the gear, since Hayward says the only kind safe for a pool is propylene glycol.[8]HaywardTriStar VS 950 Owner's Manual, IS32950VSP Rev B. Low Temp Operation note and section 8, Maintenance and Winterization.Hayward manual Both jobs belong to a pro who closes pools.
When the power comes back
Do not rush to flip the breaker. Wait for a thaw and look over every part, because Pentair notes that cracks in frozen pipes will not leak until they start to thaw.[1]PentairWinter Weather Pool Protection page, read November 24, 2026. Steps for a power outage and for severe weather.pentair.com Then put the plugs and lids back, fill the pump, start it and watch for drips. Leave the heater off until water is flowing through it.[10]PentairMasterTemp Pool and Spa Heater Installation and User's Guide. Safety warnings and the Maintenance section on cold weather and winterizing.pentair.com
If an ice storm is in the forecast and outages are likely, some owners drain the pad ahead of time and skip the worry.
A home generator can run a pool pump, but it has to be hooked up the right way by a licensed electrician. Do not rig one up in a storm.
What not to do
- Do not turn the pump off to rest it, because it is built to run for days.
- Do not shut valves to push more flow one way, since a closed line is a still line.
- Do not count on the heater, because the makers say no and it does nothing in a blackout.[10]PentairMasterTemp Pool and Spa Heater Installation and User's Guide. Safety warnings and the Maintenance section on cold weather and winterizing.pentair.com[11]RaypakDigital and Millivolt Gas Pool Heater Models 206A to 406A, Installation and Operation Manual, P/N 241236. Important Freeze Information.raypak.com
- Do not trust a pump's cold mode, which only guards the drive.[7]PentairIntelliFlo3 VSF and IntelliPro3 VSF Installation and Maintenance Guide, P/N 356231 Rev. E. Default Settings, Thermal Mode and Winterizing.pentair.com
- Do not wrap a running motor in a tarp, a blanket or plastic.[7]PentairIntelliFlo3 VSF and IntelliPro3 VSF Installation and Maintenance Guide, P/N 356231 Rev. E. Default Settings, Thermal Mode and Winterizing.pentair.com
- Do not let the water drop below the mouth of the skimmer.
- Do not pour hot water on frozen plastic or use a torch on it, because a fast change in heat can crack it.
- Do not restart frozen gear until it has thawed and you have looked it over.[1]PentairWinter Weather Pool Protection page, read November 24, 2026. Steps for a power outage and for severe weather.pentair.com
- Do not assume the warranty will help, because Pentair's pump guide says freeze damage is not covered.[7]PentairIntelliFlo3 VSF and IntelliPro3 VSF Installation and Maintenance Guide, P/N 356231 Rev. E. Default Settings, Thermal Mode and Winterizing.pentair.com Our warranty guide has more on what is.
After the freeze
When it warms up, walk the pad and look at the pump housing, the filter tank, the heater ends, the valves, the unions and the salt cell. Look for wet spots that were dry, watch the water level for a few days, and put the schedule back to normal.
If something cracked, take photos before you touch it. Our guide to freeze damage, repairs and insurance covers what tends to break and how claims work.
Then get ready for the next one by adding the freeze check to your fall list. The pool opening and closing checklist tool can build a list you can keep by the pad.
Sources
- [1]Pentair, Winter Weather Pool Protection page, read November 24, 2026. Steps for a power outage and for severe weather. pentair.com
- [2]Pentair, IntelliCenter Control System User's Guide, P/N 522990 Rev. F. Freeze Protection, Delays and Heater Operation During Freeze Protection. pentair.com (PDF)
- [3]Pentair, EasyTouch Control System User's Guide, 8 and 4 for Pool and Spa. Freeze Protection, Circuit Functions and IntelliChlor sections. pentair.com (PDF)
- [4]Jandy, AquaLink RS Owner's Manual, 6593 Rev O. Section 7.4, Freeze Protection Menu, and Important Information on Freeze Protection. jandy.com (PDF)
- [5]Hayward, OmniLogic Installation Manual, 092472 Rev L. Freeze Protection Enabled, Freeze Protection Temperature and Freeze Protect Speed settings. hayward.com (PDF)
- [6]Intermatic, PF1100 Series Freeze Protection Control, Installation, Operation and Service Manual for models PF1102T and PF1102MT. Intermatic manual (PDF)
- [7]Pentair, IntelliFlo3 VSF and IntelliPro3 VSF Installation and Maintenance Guide, P/N 356231 Rev. E. Default Settings, Thermal Mode and Winterizing. pentair.com (PDF)
- [8]Hayward, TriStar VS 950 Owner's Manual, IS32950VSP Rev B. Low Temp Operation note and section 8, Maintenance and Winterization. Hayward manual (PDF)
- [9]U.S. Department of Energy, 10 CFR 431.465(h), energy conservation standards for dedicated-purpose pool pumps with freeze protection controls. law.cornell.edu
- [10]Pentair, MasterTemp Pool and Spa Heater Installation and User's Guide. Safety warnings and the Maintenance section on cold weather and winterizing. pentair.com (PDF)
- [11]Raypak, Digital and Millivolt Gas Pool Heater Models 206A to 406A, Installation and Operation Manual, P/N 241236. Important Freeze Information. raypak.com (PDF)
- [12]Pentair, IntelliChlor Salt Chlorine Generator Installation and User's Guide, P/N 520589 Rev. R. Temperature sensor and Winterizing. pentair.com (PDF)
- [13]Leslie's, Winter Freeze: A How-To When Responding to Freezing Weather Conditions, read November 24, 2026. lesliespool.com
- [14]National Weather Service, Cold Weather Watches, Warnings and Advisories page, read November 24, 2026. Freeze Watch and Freeze Warning. weather.gov