Raypak E3T Electric Heater Diagnostic Guide

PoolDial Equipment Library• Applies to: ELS 0005, 0011, 0018, and 0027
Raypak E3T Electric Heater Diagnostic Guide

Want a guided diagnosis? Open the Raypak Heater Troubleshooter.

Raypak E3T Electric Heater Diagnostic Guide

The E3T table contains five codes. E1 and E2 stop heating and disable the buttons; E3 and E4 are ELS 0027 chamber-sensor codes that allow heating to continue; E5 describes an external-control state. Disconnect power before opening the enclosure.

Safety: Disconnect electrical power and follow the manual before opening equipment. Gas, combustion, line-voltage, pressurized-water, and refrigerant work belongs to qualified service personnel.

E3T fault codes

Display or symptomWhat it meansManual-backed check
E1The inlet sensor is shorted; buttons do not function and the heater does not heat.Replace the inlet sensor.
E2The outlet sensor is shorted; buttons do not function and the heater does not heat.Replace the outlet sensor.
E3 (ELS 0027 only)Chamber 1 sensor is shorted; the heater continues to operate and heat.Replace the chamber 1 sensor promptly.
E4 (ELS 0027 only)Chamber 2 sensor is shorted; the heater continues to operate and heat.Replace the chamber 2 sensor promptly.
E5Remote wiring is in use and the master external controller is not calling for heat.Check the external controller's call-for-heat contacts. The remote circuit must be dry-contact only; applying voltage can damage the board.

Source and model boundary

Source: Raypak E3T Electric Pool and Spa Heater Installation and Operation Manual, Fault Codes table. This guide summarizes only the listed model family. Confirm the model number and use the current manufacturer manual before service.